Series WE04 2-Piece Flanged Stainless Steel Ball Valve
Specifications - Installation and Operating Instructions
Bulletin V-WE04
T
he Series WE04 incorporates a full port
2
-piece flanged SS ball valve for great
f
low rates with minimal pressure drop.
T
he valve features a blowout proof stem
for added safety, reinforced PTFE seats
and seals for longer life, and a 316 SS
(ASTM CF8M) ball for better
p
erformance. Actuators are direct
m
ounted creating a compact assembly
f
or tight spaces. Limit switches are able
t
o be mounted directly to the valves
allowing for remote position indication.
The Series WE04 can be configured with
either a pneumatic or electric actuator.
E
lectric actuators are available in
w
eatherproof or explosion-proof, a
v
ariety of supply voltages, and two-
position or modulating control. Two-
position actuators use the supply voltage
to drive the valve open or closed, while
t
he modulating actuator accepts a 4 to 20
m
A input for valve positioning. Actuators
f
eature thermal overload protection and
p
ermanently lubricated gear train.
The pneumatic double acting actuator
uses an air supply to drive the valve open
a
nd closed. The actuator has two supply
p
orts, with one driving the valve open,
a
nd the other driving the valve closed.
S
pring return pneumatic actuators use
the air supply to open the valve, and
internally loaded springs return the valve
to the closed position. Also available is
the SN solenoid valve to electrically
s
witch the air supply pressure between
t
he air supply ports for opening and
c
losing the valve. Actuators are
constructed of anodized and epoxy
coated aluminum for years of corrosion
free service.
S
PECIFICATIONS
V
ALVE
S
ervice: Compatible liquids and gases.
Body: 2-piece.
Line Sizes: 1/2 to 3˝ .
End Connections: 150# ANSI flange.
Pressure Limits: 20˝ Hg to 275 psi
(-0.7 to 19 bar).
Wetted Materials:
Body and ball: 316 SS (CF8M);
Stem: 316 SS;
Seat: RTFE/PTFE;
Seal, Washer, and Packing: PTFE.
Temperature Limits: -20 to 392°F
(-29 to 200°C).
Other Materials:
O-ring: Fluoroelastomer;
Handle: 304 SS;
Washer: 301 SS;
Stem Nut, Locking Device,
Gland Ring: 304 SS;
Handle Sleeve: PVC.
ACTUATORS
Pneumatic “DA” and “SR” Series
Type: DA series is double acting and
SR series is spring return (rack and
pinion).
Normal Supply Pressure:
DA: 40 to 115 psi (2.7 to 7.9 bar);
SR: 80 psi (5.5 bar).
Maximum Supply Pressure: 120 psi
(8.6 bar).
Air Connections:
DA01: 1/8˝ female NPT;
DA02 to DA04: 1/4˝ female NPT;
SR02 to SR06: 1/4˝ female NPT.
Housing Material: Anodized aluminum
body and epoxy coated aluminum end
caps.
Temperature Limits: -40 to 176°F (-40
to 80°C).
Accessory Mounting: NAMUR
standard.
E
lectric “TD” and “MD” Series
P
ower Requirements: 110 VAC,
2
20 VAC, 24 VAC OR 240 VDC (MD
models not available in 24 VDC) .
Power Consumption: See page 8.
Cycle Time (per 90°):
TD01: 4 s;
MD01: 10 s;
TD02 and MD02: 20 s.
Duty Rating: 85%.
Enclosure Rating: NEMA 4X (IP67).
Housing Material: Powder coated
aluminum.
Temperature Limits: -22 to 140°F
(-30 to 60°C).
Electrical Connection: 1/2˝ female
NPT.
Modulating Input: 4 to 20 mA.
Standard Features: Manual override,
position indicator, and TD models come
with two limit switches.
Electric “TI” and “MI” Series
Power Requirements: 110 VAC,
220 VAC, 24 VAC or 24 VAC.
Power Consumption: See page 8.
Cycle Time (per 90°):
TI01 and MI01: 2.5 s;
TI02 and MI02: 5 s;
TI03 and MI03: 5 s;
TI04 and MI04: 10 s;
TI05 and MI05: 15 s.
Duty Rating:
Two-Position:
TI01-TI05: 25%;
Modulating:
MI01-MI05: 75%.
Enclosure Rating: NEMA 7
.
Housing Material: Powder coated
aluminum.
Temperature Limits: -40 to 140°F
(-40 to 60°C).
Electrical Connection: 1/2˝ female
NPT.
Modulating Input: 4 to 20 mA.
Standard Features: Position indicator
and two limit switches.
WE04-DTD01-A
W
E04-DHD00
WE04-DDA02-AA03
WE04-DDA02-NN09
WE04-CTI01-A
W.E. ANDERSON,
A DIV. OF DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S. A.
Phone: 219/879-8000 www.dwyer-inst.com
Fax: 219/872-9057 e-mail: info@dwyermail.com
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - W.E. ANDERSON

Series WE04 2-Piece Flanged Stainless Steel Ball ValveSpecifications - Installation and Operating InstructionsBulletin V-WE04The Series WE04 incorpora

Seite 2

©Copyright 2014 Dwyer Instruments, Inc. Printed in U.S.A. 7/14 FR# VA-444175-00 Rev.6W.E. ANDERSON,A DIV. OF DWYER INSTRUMENTS, INC.P.O. BOX 373 • MIC

Seite 3

VALVE BILL OF MATERIALSItem12345678910111213141516171819DescriptionBodyCapBallBall SeatJoint GasketStemThrust WasherO-RingStem PackingStem RingBellevi

Seite 4

AUTOMATED VALVE DRAWINGSW/ ELECTRIC ACTUATOREDCFBSIZE62W/ PNEUMATIC ACTUATOREDCFBSIZEW/ EXPLOSION-PROOF ELECTRIC ACTUATOREDCFBSIZEOPENSizeBCDEF1/2˝6˝1

Seite 5

PNEUMATIC ACTUATORNote: For optimal operation, pneumatic actuators should be run with a supply ofclean, lubricated air.Spring Return Actuator O

Seite 6 - FIELD WIRING

ELECTRIC ACTUATORSElectric Installation1. Operate valve manually and place in the open position. 2. Remove any mechanical stops the valve might have.

Seite 7 - OPTIONAL

Wiring Diagrams forTI01-TI10: 120 VAC, TI01-TI10: 220VAC, TI01-TI10: 24 VAC12345678910NHOT A.C. SUPPLY POWERPSC MOTORCAPACITORSW. #2OPTIONAL BRAKES

Seite 8

Page 7Wiring Diagrams forMI01-MI10: 120 VAC, MI01-MI10: 220 VAC, MI01-MI10: 24 VAC87654321654321J1J24-20mA POSITIONERPSC MOTORCAPACITORSW. 1, CLOSESW

Seite 9

Note: To speed up installation of the control wires to the ACT-MDXX modulatingactuator, it is recommended to remove the control module from the actuat

Seite 10

Page 9Electric Actuators Performance RatingMAINTENANCE/REPAIRUpon final installation of the Series WE, only routine maintenance is required. TheSeries

Kommentare zu diesen Handbüchern

Keine Kommentare